30L New Designing Low-Temperature Glycol Water Chiller Pump

Product Details
Customization: Available
After-sales Service: Support
Warranty: 1.5year
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 RMB
Plant Area
>2000 square meters
  • 30L New Designing Low-Temperature Glycol Water Chiller Pump
  • 30L New Designing Low-Temperature Glycol Water Chiller Pump
  • 30L New Designing Low-Temperature Glycol Water Chiller Pump
  • 30L New Designing Low-Temperature Glycol Water Chiller Pump
  • 30L New Designing Low-Temperature Glycol Water Chiller Pump
  • 30L New Designing Low-Temperature Glycol Water Chiller Pump
Find Similar Products

Basic Info.

Model NO.
DLSB-30/30
Type
Air-Cooled
Cooling Method
Air-cooled
Unit Structure
Integral
Selected Voltage
220V/50HZ
Compressor Number
1
Noise Level
Low
Application Fields
Chemical
Certification
ISO, CE
Name
30L Lab Cooling Water Circulating Pump
Compressor Brand
Tecumseh
Function
Digital Temperature Controller
Temperature Range
-30c-Rt
Refrigerant
R404A
Color
Light Gray
Cooling Capacity
15330-550W
Controller
Pid Controller
Power
2100W
Transport Package
Wooden Box
Specification
630*530*1000mm
Trademark
Linbel
Origin
Shanghai
Production Capacity
1000set/Month

Product Description

30L New Designing Low-Temperature Glycol Water Chiller Pump

Model

DLSB-5/30

DLSB-10/30

DLSB-20/30

DLSB-30/30

DLSB-50/30

DLSB-100/30

Technical data

Temperature range

-30-RT;±1ºC

Ambient temperature(ºC)

≤30ºC

Optimum ambient humidity

60%

Voltage(V)

220(Optional 1P 110V)

220

220(Optional 3P 220V)

 380(Optional 3P 220V/3P 480V)

Phase(P)

1

3

Frequency(Hz)

50

Power(Kw)

0.55

1

1.3

2.1

4

6

Cooling capacity(W)

RT

875

2010

2800

4600

10500

15750

0ºC

650

1650

2300

3500

9300

13250

-30ºC

255

400

600

600

1100

1100

Temperature sensor

PT100

Protection

Overvoltage, time delay, overcurrent, overheating, leakage, protector

Compressor

Type

Closed

Brand

Panasonic/Copeland

Tecumseh/Copeland

Power(Kw)

0.4

0.75

1.125

1.875

3.75

5.25

Current(A)

2

3.4

5.1

8.5

7.5

10.5

Horsepower

¾

1

2

3

6

Quantity

1

Refrigerant

R404A

Condenser

Type

Air cooling

Fan type

External rotor axial flow fan

Quantity

1

2

Evaporator

Type

Internally threaded copper pipe

Flume

Tank volume(L)

5

10

20

30

50

100

Opening diameter(mm)

180

240

320

Size(mm)

220*180

250*250

300*300

350*350

400*400

500*500

External circulation interface

G1/2" inner interface to OD 11mm pagoda interface

G1/2" inner interface to OD 14mm pagoda interface

G1/2" inner interface to OD 16mm pagoda interface

G3/4" inner interface to OD 19mm pagoda interface

Circulating pump

Type

Shield pump

Brand

Shanghai Jingyi

Power(W)

100

280

Current(A)

0.5

1.2

Rated head(m)

6

12

Rated flow(L/min)

25

35

Dimension

Chiller weight(Kg)

42

57

71

88

140

180

Packing weight(Kg)

59

78

95

113

180

230

Chiller size

Length(mm)

480

540

570

630

730

975

Width(mm)

350

420

490

530

630

760

Height(mm)

680

800

840

1000

1190

1330

Chiller packing size

Length(mm)

550

610

660

700

790

1040

Width(mm)

430

510

560

620

720

850

Height(mm)

670

870

1000

1160

1340

1490

Packing list

One valve and one roll of raw meal

3.6m insulation silicone hose

Instruction manual

Remarks

All data are measured in the factory, and users will have errors in the process of use

30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller Pump30L New Designing Low-Temperature Glycol Water Chiller PumpFAQ:
Q1. What is your products range?

• Industry water chiller, recirculating cooling chiller, rotary evaporator, alcohol recovery equipment, short path distillation kit, glass molecular distillation equipment, falling film evaporator, jacketed glass reactor and other lab equipment.

• Know more

Q2. Are you trading company or manufacturer?

• We are professional manufacture of lab equipment and we have our own factory.

Q3. Do you provide samples? Is it free?

• Yes, we could offer the sample. Considering the high value of our products, the sample is not free, but we will give you our best price including shipping cost.

Q4. Do you have warranty?

• Yes, we offer 1 year warranty for the spare part.

Q5. How long is your delivery time?

• Generally it is within 7 working days after receiving the payment if the goods are in stock. Or it is 15 working days if the goods are not in stock, depending on order quantity.

Q6. What is your terms of payment?

• Payment≤15,000USD, 100% in advance. Payment≥15,000USD, 70% T/T in advance, balance before shipment.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier